PROBLEM 2 - WATER TEMPERATURE WILL NOT CONTROL
TEMPERATURE TOO HIGH OR RUNAWAY
Remove 2” silver hole plug from brewer body.
Water temperature setpoint is controlled by lower left dial
on control board. Be sure pointer on dial is set to desired
temperature.
WATER TEMP
F)
OFF
185
190
195
200
205
10
20
30
40 50
60
70
80
SOLENOID TIMER
(WATER VOLUME)
(SECONDS)
BREW SIGNAL TIMER:
- BREW LIGHT
END OF BREW BEEPER
(MINUTES)
2
3
4
5
6
7
8
1
Check that temperature probe is properly connected to control board.
An open or disconnected probe will not control.
Temperature will runaway until the high-limit safety trips.
A shorted probe will cause a GENERAL FAULT condition
where all functions are disabled and all indicators flash.
Press and hold CANCEL key for 6 seconds to reset after
a general fault condition.
Brewer may also be reset by disconnecting from
electrical power, then reconnecting.
IMPORTANT
page7of8
temperature probe fails resistance check, replace probe p/n 83644.
Be sure to replace seal washer p/n 83731 at the same time.
temperature probe passes resistance check, and is properly connected,
replace control board p/n 83635.
For a runaway condition:
Be sure unit has sufficient water supply. Check probe as above.
HEAT indicator is on, regardless of position of water temp dial on control board,
replace control board p/n 83635.
unit continues to heat, even when HEAT indicator is not lit, replace
power board p/n 83636.
BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDE
WATER TEMPERATURE (continued)
IF
IF
IF
IF
Measure resistance of temperature probe with an ohmmeter:
Probe should read approximately 31.5k at room temperature (70ºF)
and 2.5k at brew temperature of 200ºF. Any reading less than 1k
indicates a defective temperature probe.
CONNECT TEMP
PROBE HERE
NOTE: Temperature cannot be adjusted during a brew cycle.
Turn dial fully counterclockwise to disable tank heater.