10 Sunnen DriveSt. Louis, MO 63143telephone: 314-678-6336fax: 314-781-2714www.bloomfieldworldwide.comp/n 2M-76116 Rev. J M606 100915
BREWING TEA8A. PREPARATION Examine the tea brew chamber to verify that the short the wire rack is in place. Place one (1) genuine Bloomeld pape
CLEANING INSTRUCTIONSPROCEDURE: Clean Tea BrewerPRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool.FREQUENCY: DailyTOOL
TROUBLESHOOTING SUGGESTIONS10606 Owners Manual for 8742-8748 Tea Brewer 2M-76116 606 Owners Manual for 8742-8748 Tea Brewer 2M-76116 SYMPTOM POS
SERVICING INSTRUCTIONSCAUTION: SHOCK HAZARDOpening access panels on this brew may expose uninsulated electrical components.Disconnect brewer from
SERVICING INSTRUCTIONS (continued)12TEMPERATURE ADJUSTMENTUnplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank
606 Owners Manual for 8742-8748 Tea Brewer 2M-76116 606 Owners Manual for 8742-8748 Tea Brewer 2M-76116 SERVICING INSTRUCTIONS (continued)IMPORT
SERVICING INSTRUCTIONS (continued)REPLACE HEATING ELEMENTRemove tank cover assembly (see page 13).Remove two hex nuts holding element to cover. Pull
SERVICING INSTRUCTIONS (continued)15CAUTION:CHEMICAL BURN HAZARDDeliming chemicals are caustic. Wear appropriate protective gloves and goggles during
EXPLODED VIEW: 8742 - 874816Model: 8742, 8748ICE TEA BREWING SYSTEMPL606IL1681 Rev. A 7/7/094629Purchase LocallyTube, Silicone 1”, (see above)313233
PARTS LIST: 8742 - 87488742 & 8748 PLUMBING & HOT WATER TANKFig No Part No Description1 2V-70102 TUBE VENT2 2K-70421 FTG NYLON Y 3/163 2V-7039
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f
EXPLODED VIEW (continued): 8742 - 8748 18Model: 8742, 8748ICE TEA BREWING SYSTEMPL606IL1682 Rev. C 9/15/101234567161718192010911 81213141521222324
PARTS LIST: 8742 - 874819606 Owners Manual for 8742-8748 Tea Brewer 2M-76116 606 Owners Manual for 8742-8748 Tea Brewer 2M-76116 8742 & 8748
8742 - 8748 SERVICE KITS20SOLENOID REPAIR KITS (SKINNER SOLENOID ONLY)WS-8541-120CS Coil Assembly (item 45-1)WS-8541-120K Solenoid Repair Kit (incl
8742 - 8748 WIRING DIAGRAM21606 Owners Manual for 8742-8748 Tea Brewer 2M-76116 606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
10 Sunnen Drive, St. Louis, MO 63143telephone: 314-678-6336 fax: 314-781-2714www.bloomfieldworldwide.com
1TABLE OF CONTENTSSPECIFICATIONSThank You for purchasing this Bloomeld appliance.Proper installation, professional operation and consistentmaintenanc
FEATURES AND OPERATING CONTROLS2IL1673606 Owners Manual for 8742-8748 Tea Brewer 2M-76116 606 Owners Manual for 8742-8748 Tea Brewer 2M-76116
PRECAUTIONS AND GENERAL INFORMATION3WARNING: ELECTRIC SHOCK HAZARDAll servicing requiring access to non-insulated components must be performed by qua
INSTALLATION4READ THIS CAREFULLY BEFORE STARTING THE INSTALLATIONUnpack the unit. Inspect all components for completeness and condition. Ensure that
INSTALLATION (continued)5NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes and
OPERATIONFig. 3 Brewer Operation DiagramSTART-UPFor initial start-up, or if the brewer has not been used for an extended period of time: •
OPERATION (continued)WATER HEATERWater temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to t