Résumé du contenu

Page 1

p/n 76201 Rev. F ECN-12898 M628 0

Page 2 - WARRANTY STATEMENT

OPERATION (continued) WATER HEATER Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed t

Page 3

A. PREPARATION Examine the coffee brew chamber to verify that the tall the wire rack is in place. Place one (1) genuin

Page 4

BREWING TEA 10 A. PREPARATION Examine the tea brew chamber to verify that the short the wire rack is in place. Place o

Page 5 - AGENCY LISTING INFORMATION

CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee/Tea Brewer PRECAUTIONS: Disconnect brewer from electric power. Allo

Page 6 - INSTALLATION

TROUBLESHOOTING SUGGESTIONS 12 SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won't heat Brewer unplugged or circuit breaker tripped Check powe

Page 7 - INSTALLATION (continued)

TROUBLESHOOTING SUGGESTIONS 13 SYMPTOM SUGGESTED REMEDY Poor coffee quality Keep brewer, brew chamber and decanters clean. Install a taste and odor

Page 8 - OPERATION

SERVICING INSTRUCTIONS CAUTION Electric Shock Hazard Opening access panels on this brew may expose uninsulated electrical components. Disconnect brew

Page 9

SERVICING INSTRUCTIONS 15 TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid a

Page 10 - WATER FLOW

IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure exceeds this value, or if water pressure

Page 11 - BREWING COFFEE

IMPORTANT: When replacing water faucet coil, also replace seal gaskets. SERVICING INSTRUCTIONS (continued) 17 REPLACE SOLENOID Sympto

Page 12 - BREWING TEA

NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f

Page 13 - CLEANING INSTRUCTIONS

SERVICING INSTRUCTIONS (continued) 18 REPAIR HOT WATER FAUCET Remove top panel and turn faucet valve OFF. Unscrew aerator cap from faucet and remove

Page 14 - TROUBLESHOOTING SUGGESTIONS

SERVICING INSTRUCTIONS (continued) 19 CAUTION - CHEMICAL BURN HAZARD Deliming chemicals are caustic. Wear appropriate protective gloves and goggles

Page 15

8781A EXPLODED VIEWS & PARTS LIST 20 M628 76201 Owners Manual 8781A Tea Brewer

Page 16 - SERVICING INSTRUCTIONS

8781A EXPLODED VIEWS & PARTS LIST (continued) 21 M628 76201 Owners Manual 8781A Tea Brewer

Page 17

8781A SERVICE KITS 22 SERVICE KITS FAUCET REPAIR KITS 82573 Handle 82575 Seat Cup 82576 Faucet Repair Kit (Includes Han

Page 18

8781A WIRING DIAGRAM 23 M628 76201 Owners Manual 8781A Tea Brewer

Page 19

Bloomfield Industries, Inc.Division of Carrier Commercial RefrigerationIn US and CanadaTelephone: 775-698-5700Fax: 888-492-2783Fax: 800-356-

Page 20 - SEAT CUP

MODEL VOLTS 1ø WATTS AMPS 1ø POWER SUPPLY CORD 8781A 120 VAC 1500 W 12.5 A 6' with NEMA 5-15P 1 TABLE OF CONTENTS SPECIFICATIONS Thank You f

Page 21 - CHEMICAL BURN

FEATURES AND OPERATING CONTROLS 2 M628 76201 Owners Manual 8781A Tea Brewer

Page 22

PRECAUTIONS AND GENERAL INFORMATION 3 WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by

Page 23

INSTALLATION 4 READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION Unpack the unit. Inspect all components for completeness and condition. Ensure t

Page 24 - 8781A SERVICE KITS

INSTALLATION (continued) 5 NOTE: This equipment must be installed to comply with all applicable federal, state and local plumbing codes and

Page 25 - 8781A WIRING DIAGRAM

OPERATION Fig. 3 Brewer Operation Diagram 6 M628 76201 Owners Manual 8781A Tea Brewer

Page 26

OPERATION (continued) 7 A. START-UP For initial start-up, or if the brewer has not been used for an extended period of time: